1 / 1 page Protection Relays & Controls © 2014 Littelfuse Protection Relays & Controls FPU-32 SERIES (PGR-7200) Feeder Protection Unit Description The FPU-32 Feeder Protection Unit provides integrated protection, metering, and data-logging functions. It is an excellent choice for retrofitting and upgrading older relays because of its compact size and ability to use existing CTs. The FPU-32 is used to protect distribution feeders in processing, manufacturing, petroleum, chemical, and wastewater treatment facilities. MPU-CIM (Current Input Module) (Feeder Protection Unit) (Feeder Protection Unit) GF CT L2 FPU-32 FPU-32 L1 PHASE CT PHASE CT CT PHASE CT 1-A-SECONDARY PHASE CT’s GF L2 L1 NOTE: The FPU-32 consists of the Feeder Protection Unit (pictured above) and the MPU-CIM Current Input Module (not pictured). ORDERING NUMBER COMMUNICATIONS FPU-32-00-00 TIA-232 FPU-32-01-00 TIA-232 & RS-485 FPU-32-02-00 TIA-232 & DeviceNet™ FPU-32-04-00 TIA-232 & Ethernet NOTE: One of the following is required: MPU-CIM-00-00 Current Input Module, or MPU-CTI-RT-00 Current Input Module with ring-tonque terminals. Ordering Information Simplified Circuit Diagram FEATURES BENEFITS IEC & IEEE overcurrent protection curves Definite and inverse time settings for system coordination; prevents catastrophic failures Two setpoint groups Create distinctive settings for maintenance or for two different loads Reduced overcurrent mode Maintenance mode setting to reduce the risk of arc-flash hazards Data logging On-board 100-event recorder and remote data logging helps with system diagnostics Overload Thermal protection for connected load Phase loss/Phase reverse (current) Detects unhealthy supply conditions Unbalance (current) Prevents overheating due to unbalanced phases Communications Remotely view measured values, event records & reset trips Features & Benefits A B ACCESSORIES REQUIREMENT Phase CTs Recommended Ground-Fault CT Optional MPU-16A-Y92A-96N Optional Specifications Protective Functions (IEEE Device Numbers) Input Voltage 65-265 Vac, 30 VA; 80-275 Vdc, 25 W Power-Up Time 800 ms at 120 vac Ride-Through Time 100 ms minimum 24-Vdc Source 400 mA maximum AC Measurements True RMS and DFT, Peak 32 samples/cycle and positive and negative sequence of fundamental Frequency 50, 60 Hz Output Contacts Three Form C Approvals CSA certified, CE, C-Tick (Australian), UL Recognized Communications TIA-232 (standard); TIA-485, DeviceNet™, Ethernet (optional) Analog Output 4-20 mA, programmable Conformally Coated Standard feature Warranty 10 years Mounting (Control Unit) Panel (standard) Surface (with MPU-32-SMK converter kit) (Current Input Module) DIN, Surface Overload (49, 51) Phase sequence (46) Unbalance (46) Phase loss (46) Phase CurrentTransformers Phase CTs are required to detect phase currents. Ground-Fault Transformer Zero-sequence current transformer detects ground-fault current. Available with 5-A and 30-A primary ratings for low-level pickup. B Accessories A Definite-time overcurrent (50, 51) Inverse-time overcurrent (50, 51) Ground fault (50G/N, 51G/N) RTD/PTC temperature (49) Feeder Protection–Standard Littelfuse.com/fpu-32 Rev: 4-B-121214 Based on Manual Rev: 2-A-103014 |
Codice articolo simile - FPU-32-04-00 |
|
Descrizione simile - FPU-32-04-00 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEETIT.COM |
Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |