Motore di ricerca datesheet componenti elettronici |
|
ML30.101 Scheda tecnica(PDF) 2 Page - PULS GmbH |
|
ML30.101 Scheda tecnica(HTML) 2 Page - PULS GmbH |
2 / 2 page Input Input voltage AC 100-240V (Wide Range), 47...63Hz Admiss. limits: AC 85...264V (DC 85...370V) Input current <0.6A (@ AC 100V, 25W Pout) <0.35A (@ AC 196V, 25W Pout) External fusing not required, unit provides internal fuse (T3A15H, not accessible) Transient immunity Transient resistance acc. to VDE 0160 / W2 (750V / 1.3ms), over entire load range Hold-up time (see diagram below) >19ms @ AC 100V, 5.1V / 5A >107ms @ AC 196V, 5.1V / 5A >170ms @ AC 230V, 5.1V / 5A Efficiency, Reliability Efficiency Losses >80% (AC 230V, 5.1V / 5A) (see also diagram below) typ. 6W (AC 230V, 5.1V / 5A) MTBF (Reliability) 600.000h acc. to Siemensnorm SN 29500 (5.1V / 5A, AC 230V, Tamb = +40°C) Prior to shipment, every unit undergoes the following tests in order to isolate any defective units which might suffer an early failure: • Run-in / burn-in (Full load, Tamb = +60°C, on/off cycle) • Functional test (100 %) Construction, Mechanics, Installation Robust plastic housing (US Patent No. D442, 923S), fine ventilation grid on three housing sides to keep out small parts (e.g. screws), IP20 Dimensions and weight • W x H x D •Weight 45mm x 75mm x 91mm (+ DIN Rail) Depth incl. terminals: 98 mm (+ DIN Rail) 240g Mounting orientation , or (cf. ’Output’) Ventilation/Cooling • Free space f. cooling Normal convection, no fan required recom’d.: 25mm on sides with ventilation grid Easy snap-on mounting onto the DIN-rail (TS35/7,5 or TS35/15). Unit sits safely and firmly on the rail; no tools required even to remove Connection by Spring Clamp terminals; uniformly firm hold, vibration-resistant and maintenance-free: 2 terminals per output Connector size range • flexible cable • solid cable • Wire strip length 0.3-2.5mm2 (28-12 AWG) 0.3-4mm2 (28-12 AWG) Ferrules admissible 6mm (0.24in) recommended Diagrams 0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 01 2345 67 Output current Iout [A] 0 20 40 60 80 100 120 90 125 160 195 230 Input voltage V ACin [V] Pout=25W, typ. Pout=25W, min. Pout=15W, typ. Pout=15W, min. Output characteristic Vout/Iout (@ Vout = 5.1V, typ.) Efficiency Hold-up time with ACin (@ Vout = 5.1V, typ.) (@ Vout = 5.1V, typ. + min.) 100-120V ACin 230V ACin 50 55 60 65 70 75 80 85 0,51 1,52 2,5 3 3,54 4,5 5 Output current Iout [A] 120 V ACin 230 V ACin 0 5 10 15 20 25 30 -10 0 10 20 30 40 50 60 70 Ambient temperature [°C] a b Mounting 85-150 V ACin A-a A-a A-b 150-264 V ACin A-a A-a A-a 100-370 V DCin A-a A-a A-b 85-100 V DCin B-b B-b B-c B A c Output Output voltage • preset DC 5-5.5V; adj. by front panel potentiometer 5.1V ±0.5% @ 5A Voltage regulation stat. <2% Vout dyn. ±5% Vout over all Ripple/Noise <50mVPP (20MHz bandw., 50Ω measurement) Overvoltage prot. (OVP) <6.5V Rated continuous loading Iout = 5A @ Vout = 5.1V (convection cooling); details see derating diagram below • power reserve 20%-35% (depending on Vin); for details see diagram 'output characteristic' below Overload behaviour Straight V/I characteristic (depending on Vin); details see diagr. 'output characteristic' below Protection Unit is protected against (also permanent) short-circuit, overload and open-circuit. Derating depending on built-in orientation; details see diagram below Power back immunity 10V Operating indicator Green LED Environmental Data, EMC, Safety Ambient temperature range (measured 25mm below unit) • storage/transport • operation -25°C ... +85°C -10°C ... +70°C (for derating see diagram below) Humidity max. 95% (without condensation) Electromagnetic emissions (EME) EN 61000-6-3 (includes EN 61000-6-4) Class B (EN 55011, EN 55022) Electromagnetic immunity (EMI) EN 61000-6-2 (includes EN 61000-6-1) Safe low voltage.: Prot. class/degree: SELV (EN60950, VDE0100/T.410), PELV (EN50178) Class I (EN60950) / IP20 (EN60529) The PSU complies with all major safety approvals for EU (EN 60 950, EN 60204-1, EN 50178), USA (UL 60950, E137006, UL508 LISTED, E198865), Canada (CAN/CSA-C22.2 No 60950 [CUR],CAN/CSA-C22.2 No. 14 [CUL]), CB Scheme (IEC 60950). NEC Class 2 Power Supply and Hazardous Locati- on Class I Div. 2 (UL 1604) Design details – for your advantage: • All terminals are easy to reach as mounted on the front panel. • Input and output are strictly apart from each other (input below, out- put above) and so cannot be mixed up • Mounting and connection do not require any screwdriver → Easy, quick, durable and reliable installation Technical Data ML30.101 Product information (ML30e101), Stand: 29. June 2004. Alle Angaben gelten, sofern nicht anders angegeben, für AC 230V, +25°C Umgebungstemp. und 5 min. Einlaufzeit. Sie dienen aus- schließlich der Produktbeschreibung und sind nicht als zugesicherte Eigenschaften im Rechtssinne aufzufassen. Änderungen vorbehalten. PULS GmbH, Arabellastraße 15, D-81925 Munich Tel: +49.(0)89.9278-244, Fax: +49.(0)89.9278-299, E-Mail: sales@puls-power.com www.puls-power.com Derating of output power Spri ng C lam ps |
Codice articolo simile - ML30.101 |
|
Descrizione simile - ML30.101 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEETIT.COM |
Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |