Motore di ricerca datesheet componenti elettronici |
|
ML15.241 Scheda tecnica(PDF) 11 Page - PULS GmbH |
|
ML15.241 Scheda tecnica(HTML) 11 Page - PULS GmbH |
11 / 23 page ML15.241 MiniLine-2 24V, 0.63A, SINGLE PHASE INPUT 13. EMC The power supply is suitable for applications in industrial environment as well as in residential, commercial and light industry environment without any restrictions. A detailed EMC report is available on request. EMC Immunity Generic standards: EN 61000-6-1 and EN 61000-6-2 Electrostatic discharge EN 61000-4-2 Contact discharge Air discharge 8kV 8kV Criterion A Criterion A Electromagnetic RF field EN 61000-4-3 80MHz-2.7GHz 10V/m Criterion A Fast transients (Burst) EN 61000-4-4 Input lines Output lines 4kV 2kV Criterion A Criterion A Surge voltage on input EN 61000-4-5 L N N PE, L PE 2kV 4kV Criterion A Criterion A Surge voltage on output EN 61000-4-5 + - + PE, - PE 500V 2kV Criterion A Criterion A Conducted disturbance EN 61000-4-6 0.15-80MHz 10V Criterion A Mains voltage dips EN 61000-4-11 0% of 100Vac 40% of 100Vac 70% of 100Vac 0% of 200Vac 40% of 200Vac 70% of 200Vac 0Vac, 20ms 40Vac, 200ms 70Vac, 500ms 0Vac, 20ms 80Vac, 200ms 140Vac, 500ms Criterion A Criterion C Criterion A Criterion A Criterion A Criterion A Voltage interruptions EN 61000-4-11 0Vac, 5000ms Criterion C Input voltage swells PULS internal standard 300Vac, 500ms Criterion A Powerful transients VDE 0160 over entire load range 750V, 1.3ms Criterion A Criterions: A: Power supply shows normal operation behavior within the defined limits. C: Temporary loss of function is possible. Power supply may shut-down and restarts by itself. No damage or hazards for the power supply will occur. EMC Emission Generic standards: EN 61000-6-3 and EN 61000-6-4 Conducted emission EN 55011, EN 55022, FCC Part 15, CISPR 11, CISPR 22 Class B, input lines Radiated emission EN 55011, EN 55022 Class B Harmonic input current EN 61000-3-2 Not applicable below 75W input power Voltage fluctuations, flicker EN 61000-3-3 fulfilled This device complies with FCC Part 15 rules. Operation is subjected to following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Switching frequency Constant, typ. 65kHz Mar. 2013 / Rev. 2.1 DS-ML15.241-EN All parameters are specified at 24V, 0.63A, 230Vac input, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 11/23 |
Codice articolo simile - ML15.241 |
|
Descrizione simile - ML15.241 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEETIT.COM |
Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |