3 / 7 page 408- 9359 3 of 7 Rev C 3.2. Wire Insertion Depth A. Wire Too Deep in Contact Slot 1. Remove the head and turn the adjuster 1/6--turn CLOCKWISE (See Figure 3). This will reduce the wire insertion depth by approximately 0.20 mm [.008 in.]. 2. Make a test termination according to the procedure given in Section 4, TERMINATION PROCEDURE, and inspect the termination in accordance with Section 5, INSPECTION. Readjust if required. Figure 3 Turn CLOCKWISE to Reduce Wire Insertion Depth Adjuster Turn COUNTERCLOCKWISE for Deeper Wire Insertion NOTE: 1/6 Turn Equals 0.20 mm [.008 in.] Adjustment B. Wire Not Deep Enough in Contact Slot Manual Handle Assembly 1. Remove the head and turn the adjuster 1/6--turn COUNTERCLOCKWISE (See Figure 3). This will increase wire insertion depth by approximately 0.20 mm [.008 in.]. 2. Make a test termination according to the procedure given in Section 4, TERMINATION PROCEDURE, and inspect the termination in accordance with Section 5, INSPECTION. Readjust if required. Pneumatic Handle Assembly 1. Increase the air pressure by 69 kPa [10 psi], and make a test termination according to the procedure given in Section 4, TERMINATION PROCEDURE. 2. Check the termination in accordance with Section 5, INSPECTION. 3. If the wire is still not inserted deeply enough, repeat Steps 1 and 2, until proper insertion depth is obtained or the air pressure is set to 483 kPa [70 psi]. If proper insertion depth is not obtained at 483 kPa [70 psi], reduce the air pressure to 276 kPa [40 psi] and follow the preceding procedure for the manual handle assembly. 4. TERMINATION PROCEDURE Discrete wire, jacketed cable with individual insulated conductors, and ribbon cable can be terminated in the head. See Figure 5 for required preparation for the various types. Keep these things in mind when terminating wire in contact housing assemblies; A. Individual housing assemblies of less than six positions cannot be terminated in the head. If you need to terminate one housing assembly which has less than six positions, (e.g., when making repairs), you can use a strip--form housing assembly, terminate the first housing assembly on the strip, push the carrier strip through the head, and break the housing assembly off the carrier strip. The remaining housing assemblies on the strip can be terminated in the same way as needed. B. When terminating 6-- through 9--position individual housing assemblies, you must use another housing assembly to push the housing assembly against the wire inserter. Remove the “pusher” housing assembly before terminating any wires. C. The following insulation diameters must be observed: Manual Handle Assembly 58074--1 0.76--1.37 mm [.030--.054 in.] Pneumatic Handle Assembly 58075--1 0.76--1.14 mm [.030--.045 in.] Pneumatic Power Bench Assembly 58338--1 0.76--1.37 mm [.030--.054 in.] Electric Bench Machine 931800--1 0.76--1.37 mm [.030--.054 in.] D. When terminating wire with an insulation diameter of less than 1.02 mm [.040 in.], make sure that the wire is straight and that it is aligned with the wire slot. E. When terminating wire with an insulation diameter of less than 1.02 mm [.040 in.], lower yields will be experienced. The termination procedure follows, (see Figure 4): 1. Refer to the table in Figure 1 and select a housing assembly for the wire size to be terminated. Make sure the contacts are properly seated in the housing assembly with each contact locking lance in a preload window, each preload forward stop at the back of the housing assembly, and the carrier strip properly interlocked. |
Codice articolo simile - 2--22285--6 |
|
Descrizione simile - 2--22285--6 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEETIT.COM |
Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |