Motore di ricerca datesheet componenti elettronici |
|
SS443R Scheda tecnica(PDF) 2 Page - Honeywell Solid State Electronics Center |
|
SS443R Scheda tecnica(HTML) 2 Page - Honeywell Solid State Electronics Center |
2 / 4 page SS340RT and SS440R Series 2 www.honeywell.com/sensing Table 1. SS340RT and SS440R Series Specifications (At Vs=3.0 to 24 Vdc, 20 mA load, TA = -40 ºC to 150 ºC [-40 ºF to 257 ºF]) Characteristic Condition Minimum Typical Maximum Unit Supply voltage: 1 SS440R Series -40 °C to 150 °C [-40 °F to 302 °F] 3 – 24 SS340RT Series -40 °C to 125 °C [-40 °F to 257 °F] 3 – 24 SS340RT Series 150 °C [302 °F] 3 – 12 Vdc Supply current Vsupply = 5 V at 25 °C [77 °F] Vsupply = 3 V at 25 °C [77 °F] – – – 4 3.5 – 6 5 8 mA Vsat at 20 mA, gauss >Bop – – 0.4 Vdc Output leakage current gauss >Bop – – 10 µA Output switching time: rise fall Vsupply = 12 V at 25 °C [77 °F], R L =1.6 kOhm, CL = 20 pF – – – – 1.5 1.5 µs Thermal resistance: SS440R Series 233 SS340RT Series – – 303 – °C/W Operate: SS341RT/SS441R 35 85 135 SS343RT/SS443R 45 125 205 SS349RT/SS449R – 240 350 460 gauss Release: SS341RT/SS441R 10 50 120 SS343RT/SS443R 40 90 180 SS349RT/SS449R – 135 250 370 gauss Differential: SS341RT/SS441R 5 35 80 SS343RT/SS443R 5 35 120 SS349RT/SS449R – 30 100 170 gauss Operating temperature – -40 [-40] – 150 [302] °C [°F] Storage temperature – -40 [-40] – 150 [302] °C [°F] Note 1. See Figure 1. Table 2. SS340RT and SS440R Series Absolute Maximum Ratings 1 Characteristic Minimum Typical Maximum Unit Supply voltage -28.0 – 28.0 V Applied output voltage -0.5 – 28.0 V Output current – – 20 mA Magnetic flux – – no limit gauss Note 1: The magnetic field strength (gauss) required to cause the switch to change state (operate and release) will be as specified in the magnetic characteristics. To test the switch against the specified magnetic characteristics, the switch must be placed in a uniform magnetic field. NOTICE Absolute maximum ratings are the extreme limits that the device will withstand without damage to the device. However, the electrical and mechanical characteristics are not guaranteed as the maximum limits (above recommended operating conditions) are approached, nor will the device necessarily operate at absolute maximum ratings. Figure 1. SS340RT Series Rated Supply Voltage Figure 2. Current Sinking Output Block Diagram |
Codice articolo simile - SS443R |
|
Descrizione simile - SS443R |
|
|
Link URL |
Privacy Policy |
ALLDATASHEETIT.COM |
Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |