8 / 16 page
STK14CA8
Document Number: 001-51592 Rev. **
Page 8 of 16
Software Controlled STORE/RECALL Cycle
Figure 11. Software STORE/RECALL CYCLE: E Controlled[13]
Figure 12. Software STORE/RECALL CYCLE: G Controlled[13]
NO.
Symbols
Parameter[12,13]
STK14CA8-35 STK14CA8-35 STK14CA8-45
Units Notes
E Cont G Cont
Alt
Min
Max
Min
Max
Min
Max
26
tAVAV
tAVAV
tRC
STORE/RECALL Initiation Cycle
Time
25
35
45
ns
13
27
tAVEL
tAVGL
tAS
Address Setup Time
0
0
0
ns
28
tELEH
tGLGH
tCW
Clock Pulse Width
20
25
30
ns
29
tEHAX
tGHAX
Address Hold Time
1
1
1
ns
30
tRECALL tRECALL
RECALL Duration
50
50
50
μs
26
26
27
28
29
23
30
26
26
27
28
29
23
30
Notes
12. The software sequence is clocked on the falling edge of E controlled READs or G controlled READs
13. The six consecutive addresses must be read in the order listed in the Software STORE/RECALL Mode Selection Table. W must be high during all six consecutive cycles.
[+] Feedback