Motore di ricerca datesheet componenti elettronici |
|
HCPL-0723-500 Scheda tecnica(PDF) 6 Page - Agilent(Hewlett-Packard) |
|
HCPL-0723-500 Scheda tecnica(HTML) 6 Page - Agilent(Hewlett-Packard) |
6 / 12 page 6 All Agilent data sheets report the creepage and clearance inherent to the optocoupler component itself. These dimensions are needed as a starting point for the equipment designer when determining the circuit insulation requirements. However, once mounted on a printed circuit board, minimum creepage and clearance requirements must be met as specified for individual equipment standards. For creepage, the shortest distance path along the surface of a printed circuit board between the solder fillets of the input and output leads must be considered. There are recommended techniques such as grooves and ribs, which may be used on a printed circuit board to achieve desired creepage and clearances. Creepage and clearance distances will also change depending on factors such as pollution degree and insulation level. VDE 0884 Insulation Related Characteristics (Option 060) HCPL-7723 HCPL-0723 Description Symbol Option 060 Option 060 Units Installation classification per DIN VDE 0110/1.89, Table 1 for rated mains voltage ≤ 150 V rms I-IV I-IV for rated mains voltage ≤ 300 V rms I-IV I-III for rated mains voltage ≤ 450 V rms I-III Climatic Classification 55/85/21 55/85/21 Pollution Degree (DIN VDE 0110/1.89) 2 2 Maximum Working Insulation Voltage VIORM 630 560 V peak Input to Output Test Voltage, Method b* VPR 1181 1050 V peak VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec, Partial Discharge < 5 pC Input to Output Test Voltage, Method a* VPR 945 840 V peak VIORM x 1.5 = VPR, Type and Sample Test, tm = 60 sec, Partial Discharge < 5 pC Highest Allowable Overvoltage* VIOTM 6000 4000 V peak (Transient Overvoltage, tini = 10 sec) Safety Limiting Values (maximum values allowed in the event of a failure, also see Thermal Derating curve, Figure 11) Case Temperature TS 175 150 °C Input Current IS,INPUT 230 150 mA Output Power PS,OUTPUT 600 600 mW Insulation Resistance at TS, VIO = 500 V RIO ≥ 109 ≥ 109 Ω *Refer to the front of the optocoupler section of the Isolation and Control Component Designer’s Catalog, under Product Safety Regulations section (VDE 0884), for a detailed description. Note: These optocouplers are suitable for “safe electrical isolation” only within the safety limit data. Maintenance of the safety data shall be ensured by means of protective circuits. Note: The surface mount classification is Class A in accordance with CECC 00802. |
Codice articolo simile - HCPL-0723-500 |
|
Descrizione simile - HCPL-0723-500 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEETIT.COM |
Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |