7 / 36 page MLX90616ESF-HCA Infra Red Thermometer in TO-39 for high temperature thermometer guns 3901090616 Page 7 of 36 Data Sheet Rev 002 August 20, 2012 Parameter Symbol Test Conditions Min Typ Max Units SMBus compatible 2-wire interface 2 Input high voltage VIH(Ta,V) Over temperature and supply VDD-0.1 V Input low voltage VIL(Ta,V) Over temperature and supply 0.6 V Output low voltage VOL SDA pin in open drain mode, over temperature and supply, Isink = 2mA 0.25 V SCL leakage ISCL,leak VSCL=3V, Ta=+85°C 20 uA SDA leakage ISDA,leak VSDA=3V, Ta=+85°C 0.25 uA SCL capacitance CSCL 10 pF SDA capacitance CSDA 10 pF Slave address SA Factory default 5A hex Wake up request twake SDA low 33 ms SMBus Request tREQ SCL low 1.44 ms Timeout,low Timeout,L SCL low 27 33 ms Timeout, high Timeout,H SCL high 45 55 us Acknowledge setup time Tsuac(MD ) 8-th SCL falling edge, Master 0.5 1.5 us Acknowledge hold time Thdac(MD ) 9-th SCL falling edge, Master 1.5 2.5 us Acknowledge setup time Tsuac(SD) 8-th SCL falling edge, Slave 2.5 us Acknowledge hold time Thdac(SD ) 9-th SCL falling edge, Slave 1.5 us EEPROM Data retention Ta = +85°C 10 years Erase/write cycles Ta = +25°C 100,000 Times Erase/write cycles Ta = +125°C 10,000 Times Erase cell time Terase 5 ms Write cell time Twrite 5 ms Table 3: Electrical specification MLX90616BXX Notes: All the communication and refresh rate timings are given for the nominal calibrated HFO frequency and will vary with this frequency’s variations. 1. All PWM timing specifications are given for single PWM output. With large capacitive loads, a lower PWM frequency is recommended. Thermal relay output (when configured) has the PWM DC specification and can be programmed as push- pull, or NMOS open drain. PWM is free-running; power-up factory default is SMBus. 2. For SMBus compatible interface on 12V application refer to Application information section. SMBus compatible interface is described in details in the SMBus detailed description section. The maximum number of MLX90616xxx devices on one bus is 127, higher pull-up currents are recommended for higher number of devices, faster bus data transfer rates, and increased reactive loading of the bus. The MLX90616 is always a slave device on the bus. The MLX90616 can work in both low-power and high-power SMBus communication. All voltages are referred to the Vss (ground) unless otherwise noted. |
Codice articolo simile - MLX90616ESF-HCA-000-TU |
|
Descrizione simile - MLX90616ESF-HCA-000-TU |
|
|
Link URL |
Privacy Policy |
ALLDATASHEETIT.COM |
Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |