Motore di ricerca datesheet componenti elettronici |
|
LF06P2-W4F-840-P Scheda tecnica(PDF) 2 Page - OSRAM GmbH |
|
LF06P2-W4F-840-P Scheda tecnica(HTML) 2 Page - OSRAM GmbH |
2 / 4 page www.osram.com/flex Due to the special conditions of manufacturing processes of LED, the typical data of technical parameters can only reflect statistical figures and do not necessarily correspond to the actual parameters of each single product which could differ from the typical data. Subject to change without notice. Errors and omissions excepted. Version: 2016-07-12 LINEARlight POWER Flex® Protect G2.1 (2016) – LF06P2-P 2/4 Technical operating data (for overall module) Product Order Code Voltage [V] Power [W] Current [A] Luminous Flux [lm] Radiance Angle [°] Overall Length LF06P2-W4F-830-P 4052899400030. 24 79.1 3.3 6380 120 5.1 m LF06P2-W4F-835-P 4052899372771 24 71.4 3.0 6890 120 5.1 m LF06P2-W4F-840-P 4052899372795 24 71.4 3.0 7140 120 5.1 m LF06P2-W4F-860-P 4052899372818 24 71.4 3.0 7140 120 5.1 m LF06P2-W4F-890-P 4052899372832 24 79.1 3.0 7140 120 5.1 m Minimum & maximum ratings Operating temperature at Tc-Point [°C] Storage temperature [°C] Voltage range [V dc] Reverse Voltage [V dc] LF06P2-P - 20 … +50°C - 40 … +100°C 23 … 25 V 24 V ► Exceeding maximum ratings for operating and storage temperature will reduce expected life time or destroy the LED Module. ► Exceeding maximum ratings for operating voltage will cause hazardous overload and will likely destroy the LED Module. ► The temperature of the LED module must be measured at the Tc-point according to EN60598-1 in a thermally constant status with a temperature sensor or a temperature sensitive label. For exact location of the Tc-point see drawing below. Technical drawing Safety information ► The module has to be protected from mechanical loads ► Assembly must not damage or destroy conducting paths on the circuit board. ► Installation of LED modules (with power supplies) needs to be made with regard to all applicable and safety standards. Only qualified personnel should be allowed to perform installations. ► Observe correct polarity! Depending on the product incorrect polarity will lead to emission of no light. The module can be damaged after a few seconds. To prevent this, correct polarity immediately! (see "reverse voltage", page 2) ► Parallel connection is highly recommended as safe electrical operation mode. Serial connection is not recommended. Unbalanced voltage drop can cause hazardous overload the LED module. ► ESD protection methods have to be observed when cutting and connecting the module. Check on ESD handling in the application note ESD protection for LED modules. ► The LED Module must not be operated under water ► Please ensure that the power supply is of adequate power to operate the total load. |
Codice articolo simile - LF06P2-W4F-840-P |
|
Descrizione simile - LF06P2-W4F-840-P |
|
|
Link URL |
Privacy Policy |
ALLDATASHEETIT.COM |
Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |