Motore di ricerca datesheet componenti elettronici
  Italian  ▼
ALLDATASHEETIT.COM

X  

CAR2012TEBXXZ01A Scheda tecnica(PDF) 11 Page - Lineage Power Corporation

Il numero della parte CAR2012TEBXXZ01A
Spiegazioni elettronici  Universal input with PFC Constant power characteristic 2 front panel LEDs: 1-input;2
Download  20 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Produttore elettronici  LINEAGEPOWER [Lineage Power Corporation]
Homepage  http://www.lineagepower.com
Logo LINEAGEPOWER - Lineage Power Corporation

CAR2012TEBXXZ01A Scheda tecnica(HTML) 11 Page - Lineage Power Corporation

Back Button CAR2012TEBXXZ01A Datasheet HTML 7Page - Lineage Power Corporation CAR2012TEBXXZ01A Datasheet HTML 8Page - Lineage Power Corporation CAR2012TEBXXZ01A Datasheet HTML 9Page - Lineage Power Corporation CAR2012TEBXXZ01A Datasheet HTML 10Page - Lineage Power Corporation CAR2012TEBXXZ01A Datasheet HTML 11Page - Lineage Power Corporation CAR2012TEBXXZ01A Datasheet HTML 12Page - Lineage Power Corporation CAR2012TEBXXZ01A Datasheet HTML 13Page - Lineage Power Corporation CAR2012TEBXXZ01A Datasheet HTML 14Page - Lineage Power Corporation CAR2012TEBXXZ01A Datasheet HTML 15Page - Lineage Power Corporation Next Button
Zoom Inzoom in Zoom Outzoom out
 11 / 20 page
background image
GE
Data Sheet
CAR2012TE series rectifier
Input: 85Vac to 264Vac; Output: 12 Vdc @ 2000W; 3.3Vdc or 5 Vdc @ 4A
February 9, 2014
©2013 General Electric Company. All rights reserved.
Page 11
The Linear Data Format is a two byte value with an 11-bit,
two’s complement mantissa and a 5-bit, two’s complement
exponent or scaling factor, its format is shown below.
Data Byte High
Data Byte Low
Bit 7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
Exponent (E)
Mantissa (M)
The relationship between the Mantissa, Exponent, and Actual
Value (V) is given by the following equation:
E
M
V
2
Where:
V is the value
M is the 11-bit, two’s complement mantissa
E is the 5-bit, two’s complement exponent
Standard features
Command
Comments
ON_OFF_CONFIG
Both the CNTL pin, enabling or disabling
the output, and the OPERATION command
are supported. Other options are not
supported.
Vout_OV_fault_response
Only latched (0x80) is supported
CAPABILITY
400KHz, SMBALERT
PMBus revision
1.2
PMBusTM Command set:
Non-supported commands are annunciated.
Command
Hex
Code
Data
Byte
Function
Operation
0x01
1
Output ON/OFF
ON_OFF_config
0x02
1
09, output ON default
Clear_faults
0x03
0
Clear Status
Write_protect
0x10
1
Write control
Restore_default_all
0x12
0
Reset defaults
Store_default_code
0x13
1
Change default state
Vout_mode
0x20
1
Vout constants
Vout_command
0x21
2
Set Vout
Fan_command_1
0x3B
2
Set fan speed in %
Vout_OV_fault_limit
0x40
2
Set OV fault limit
Vout_OV_warn_limit
0x42
2
Set OV warn limit
Iout_OC_fault_limit
0x46
2
Iout_OC_fault_response4
0x47
1
Latch or hiccup
Iout_OC_warn_limit
0x4A
2
Set OC warn limit
OT_fault_limit
0x4F
2
OT_fault_response5
0x50
1
Latch or hiccup
OT_warn_limit
0x51
2
Set OT warn limit
Status_byte
0x78
1
Status_word
0x79
2
Status_Vout
0x7A
1
Status_Iout
0x7B
1
Status_input
0x7C
1
Status_temperature
0x7D
1
Status_CML
0x7E
1
Status_fan_1_2
0x81
1
Read_Iin
0x89
2
4
Only latched (0xC0) or hiccup (0xF8) are supported
5
Only latched (0x80) or restart (0xC0) are supported
Command
Hex
Code
Data
Byte
Function
Read_Vout
0x8B
2
Read_Iout
0x8C
2
Read_temperature
0x8D
2
Read_fan_speed_1
0x90
2
Read_fan_speed_2
0x91
2
Read_Pin
0x97
2
Mfr_ID
0x99
5
Mfr_model
0x9A
16
CAR2012TEXXXZ01A
Mfr_serial
0x9E
15
01KZ51018193xxx
Read_Std_Parameters
0xD0
10
Read_Status_State
0xD1
2
Read_Alarm_State
0xD2
2
Read_fan_speed
0xD3
4
Read_Input_string
0xD4
2
Read_mfr_rev
0xD5
4
Read_Run_Timer
0xD6
3
EEPROM_record
0xD9
64
Test Function
0xDF
1
Command Descriptions
Operation (0x01) : By default the Power supply is turned ON
at power up as long as Power ON/OFF signal pin is active HI.
The Operation command is used to turn the Power Supply ON
or OFF via the PMBus. The data byte below follows the
OPERATION command.
FUNCTION
DATA BYTE
Unit ON
80
Unit OFF
00
To RESET the power supply cycle the power supply OFF, wait
at least 2 seconds, and then turn back ON. All alarms and
shutdowns are cleared during a restart.
Clear_faults (0x03): This command clears all STATUS and
FAULT registers and resets the SMBAlert# line.
If a fault still persists after the issuance of the clear_faults
command the specific registers indicating the fault are reset
and the SMBAlert# line is activated again.
WRITE_PROTECT register (0x10): Used to control writing to
the PMBus device. The intent of this command is to provide
protection against accidental changes. All supported
command parameters may have their parameters read,
regardless of the write_protect settings. The default setting of
this register is disable_all_writes except write_protect 0x80h.
FUNCTION
DATA BYTE
Enable all writes
00
Disable all writes except write_protect
80
Disable all writes except write_protect and
OPERATION
40
Restore_Default_All (0x12): Restores all register values and
responses to the default parameters set in the power supply.


Codice articolo simile - CAR2012TEBXXZ01A

Produttore elettroniciIl numero della parteScheda tecnicaSpiegazioni elettronici
logo
Riedon Powertron
CAR2010 RIEDON-CAR2010 Datasheet
251Kb / 1P
   Thin Film Precisionion Chip Resistor
CAR2010 RIEDON-CAR2010 Datasheet
168Kb / 2P
   Thin Film Precision Chip Resistor
CAR2010 RIEDON-CAR2010 Datasheet
145Kb / 3P
   CAR Series
More results

Descrizione simile - CAR2012TEBXXZ01A

Produttore elettroniciIl numero della parteScheda tecnicaSpiegazioni elettronici
logo
Lineage Power Corporati...
CAR1248TN LINEAGEPOWER-CAR1248TN_14 Datasheet
266Kb / 8P
   Universal input with PFC Constant power characteristic 3 front panel LEDs: 1-input;2-output; 3 - fault
CAR1248FP LINEAGEPOWER-CAR1248FP_14 Datasheet
264Kb / 11P
   Universal input with PFC Constant power characteristic 3 front panel LEDs: 1-input;2-output; 3 - fault
CAR2024FP LINEAGEPOWER-CAR2024FP_14 Datasheet
261Kb / 7P
   Universal input with PFC Constant power characteristic front panel LEDs: input, output, fault
CAR1612FP LINEAGEPOWER-CAR1612FP_14 Datasheet
293Kb / 7P
   Universal input with PFC Constant power characteristic 2 front panel LED 1-input LED 2-[output, fault, over temp]
logo
HITRON ELECTRONICS CORP...
HVP950 HITRON-HVP950 Datasheet
129Kb / 2P
   UNIVERSAL INPUT HARMONIC CORRECTION(PFC)
HEMP252G HITRON-HEMP252G Datasheet
84Kb / 2P
   UNIVERSAL INPUT HARMONIC CORRECTION (PFC)
HEMP250G HITRON-HEMP250G Datasheet
84Kb / 2P
   UNIVERSAL INPUT HARMONIC CORRECTION (PFC)
HEMP150G HITRON-HEMP150G Datasheet
54Kb / 2P
   UNIVERSAL INPUT HARMONIC CORRECTION (PFC)
HIMP151 HITRON-HIMP151_11 Datasheet
997Kb / 2P
   UNIVERSAL INPUT HARMONIC CORRECTION(PFC)
HVP300 HITRON-HVP300 Datasheet
131Kb / 2P
   UNIVERSAL INPUT HARMONIC CORRECTION(PFC)
More results


Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20


Scheda tecnica Scarica

Go To PDF Page


Link URL




Privacy Policy
ALLDATASHEETIT.COM
Lei ha avuto il aiuto da alldatasheet?  [ DONATE ] 

Di alldatasheet   |   Richest di pubblicita   |   contatti   |   Privacy Policy   |   scambio Link   |   Ricerca produttore
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com