Motore di ricerca datesheet componenti elettronici |
|
CA3-B0-10-450-121-C Scheda tecnica(PDF) 5 Page - Carling Technologies |
|
CA3-B0-10-450-121-C Scheda tecnica(HTML) 5 Page - Carling Technologies |
5 / 24 page 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com C-Series – General Specifications | 5 Mechanical Physical Environmental Electrical Maximum Voltage Current Rating Standard Voltage Coils Auxiliary Switch Rating Insulation Resistance Dielectric Strength Resistance, Impedance Pulse Tolerance Curves Endurance Trip Free Trip Indication Number of Poles Internal Circuit Configuration Weight Standard Colors Shock Vibration Moisture Resistance Salt Spray Thermal Shock Operating Temperature Designed and tested in accordance with requirements of specification MIL-PRF-55629 & MIL-STD-202 as follows: AC, 480 WYE/277 VAC, 50/60 Hz (see Table A.) UL489: AC,240 VAC. (Table D), 50/60 Hz, 125 VDC, UL 1077, 150 VDC, 277 VAC Standard current coils: 0.100, 0.250, 0.500, 0.750, 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, 25.0, 30.0, 35.0, 40.0, 50.0, 60.0, 70.0, 80.0, 90.0 and 100 amps. Other ratings available, see Ordering Scheme. DC - 6V, 12V; AC - 120V; other ratings available, see Ordering Scheme. SPDT; 10.1 amps-250VAC, DC Aux. Switch 1.0A, 65 VDC. 0.5A, 80VDC,1/4 HP, 125VAC,VDE & TUV 1.0 125 VAC. Minimum of 100 Megohms at 500 VDC. UL, CSA: 1960 V 50/60 Hz for one minute between all electrically isolated terminals. C-Series Circuit Breakers comply with the 8mm spacing and 3750V 50/60 Hz dielectric requirements from hazardous voltage to operator accessible surfaces, between adjacent poles and from main circuits to auxiliary circuits per Publications EN 60950 and VDE 0805. Values from Line to Load Terminal based on Series Trip Circuit Breaker. 10,000 ON-OFF operations @ 6 per minute; with rated current & voltage All C-Series circuit breakers will trip on overload, even when actuator is forcibly held in the ON position. The operating actuator moves positively to the OFF position when an overload causes the breaker to trip. With mid-trip, handle moves to the mid position on electrical trip of the circuit breaker. With mid trip handle with alarm switch, handle moves to the mid position and the alarm switch actuates when the circuit breaker is electrically tripped. 1-6 poles ≤ 50A; 1-4 poles @ 51- 70A; 1-2 poles 71-100A. UL489 Handle: 1 pole ≤ 100A, 2 pole ≤ 50A; Rocker: 1 pole ≤ 100A. Series (with or without auxiliary switch, mid trip & mid trip with alarm switch) Shunt & Relay with current or voltage trip coils, Dual Coil, Switch Only (with or without aux. switch). UL489: Series (with or without auxiliary switch, mid-trip & mid-trip with alarm switch). Approx.112 grams/pole ( 3.95 oz). Housing: Black Withstands 100 Gs, 6ms sawtooth while carrying rated current per Method 213, Test Condition “I”. Instantaneous and ultrashort curves tested @ 90% of rated current. Withstands 0.060” excursion from 10-55 Hz & 10 Gs 55-500 Hz, @ rated current per Method 204C, Test Cond. A. Instantaneous & ultrashort curves tested @ 90% of rated current. Method 106D, i.e., ten 24-hour cycles @ +25°C to +65°C, 80-98% RH. Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs). Method 107D, Condition A (five cycles @ -55°C to +25°C to +85°C to +25°C). -40°C to +85°C 0.1 0.1 0.01 0.001 0.01 1 10 100 1000 ± 15% ± 25% ± 35% 1 100 10 TOLERANCE (%) O H M S CURRENT (AMPS) FIGURE 1 0.100 - 5.0 5.1 - 20.0 20.1 - 100 RESISTANCE, IMPEDANCE VALUES from Line to Load Terminals (Values Based on Series Trip Circuit Breaker ) AMPERE RATING Time Delay Curves 42, 44 & 46 (50 Amps Max.) 16.67 t rI 4.165 8.33 25x 12x 20.0 Time Delay Curves 22, 24 (100 Amps Max.) 26 (70 Amps Max.) Time in Milliseconds t Time Delay Curves 22, 24 (100 Amps Max.) 26 (70 Amps Max.) 60 Hz 1/2 Cycle Inrush Pulse Tolerance 50 Hz 1/2 Cycle Inrush Pulse Tolerance 10.0 Time Delay Curves 42, 44 & 46 (50 Amps Max.) 22x 10x 5.0 rI Time Delay Curves 42, 44 & 46 (50 Amps Max.) 16.67 t rI 4.165 8.33 25x 12x 20.0 Time Delay Curves 22, 24 (100 Amps Max.) 26 (70 Amps Max.) Time in Milliseconds t Time Delay Curves 22, 24 (100 Amps Max.) 26 (70 Amps Max.) 60 Hz 1/2 Cycle Inrush Pulse Tolerance 50 Hz 1/2 Cycle Inrush Pulse Tolerance 10.0 Time Delay Curves 42, 44 & 46 (50 Amps Max.) 22x 10x 5.0 rI CURRENT (AMPS) 0.10 - 5.0 5.1 - 20.0 ± 15% ± 25% TOLERANCE (%) 20.1 - 100.0 ± 35% |
Codice articolo simile - CA3-B0-10-450-121-C |
|
Descrizione simile - CA3-B0-10-450-121-C |
|
|
Link URL |
Privacy Policy |
ALLDATASHEETIT.COM |
Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |