Motore di ricerca datesheet componenti elettronici |
|
P00 Scheda tecnica(PDF) 2 Page - Mean Well Enterprises Co., Ltd. |
|
P00 Scheda tecnica(HTML) 2 Page - Mean Well Enterprises Co., Ltd. |
2 / 3 page SPECIFICATION PQ-100D PQ-100E MODEL DCVOLTAGE RATEDCURRENT CURRENTRANGE RATEDPOWER OUTPUT VOLTAGE ADJ.RANGE LINEREGULATION LOADREGULATION SETUP,RISETIME HOLDTIME (Typ.) VOLTAGERANGE FREQUENCY RANGE EFFICIENCY (Typ.) INPUT INRUSHCURRENT (Typ.) LEAKAGECURRENT WORKINGTEMP. POWERGOOD WORKINGHUMIDITY STORAGETEMP.,HUMIDITY TEMP.COEFFICIENT VIBRATION MTBF DIMENSION OTHERS NOTE PACKING OVERLOAD ACCURRENT (Typ.) 5V 24V -12V 5V 15V 12V 24V 5A 2A 0.5A 8A 0.6A 3A 0.6A 2~5A 0.4~2A 0.5~4.5A 0~1A 2~8A 0~1A 0.5~3A 0~1A 103W 99.4W 80mVp-p 180mVp-p 120mVp-p 120mVp-p 150mVp-p 120mVp-p 120mVp-p 80mVp-p CH1:4.75~5.5V CH1:4.75~5.5V 2.0% 10% 6.0% 6.0% 6.0% 6.0% 6.0% 2.0% 1.0% 1.0% 1.0% 5.0% 1.0% 1.0% 1.0% 3.0% 1.0% 1.0% 1.0% 1.0% 5.0% 3.0% 1.0% 5.0% 1200ms,50msatfullload 80msatfullload 100~264VAC141~370VDC(90~100VAC90%loadmax.) 47~63Hz 77% 74% 3A/115VAC1.5A/230VAC COLDSTART 50A <1mA /240VAC 105%~135% ratedoutputpower Protectiontype: Hiccupmode,recoversautomaticallyafterfaultconditionisremoved Protectiontype: Hiccupmode,recoversautomaticallyafterfaultconditionisremoved -10~+50 ,60 withcoolingfan(Referto"DeratingCurve") 1ms 20~90%RHnon-condensing -20~+85 ,10~95%RH 0.03%/ (0~50 ) 10~500Hz,2G10min./1cycle,periodfor60min. eachalongX, Y,Zaxes 258.6Khrsmin.MIL-HDBK-217F(25 ) 177.8*107.95*46.5mm(L*W*H) 0.56Kg;24pcs/14.5Kg/1.19CUFT FileName:PQ-100-SPEC 2012-02-03 CH1:5.75~6.75VDC OVERVOLTAGE SAFETY STANDARDS UL60950-1, TUVEN60950-1approved CompliancetoEN55022(CISPR22)ClassB, EN61000-3-2,-3 Complianceto lightindustrylevel,criteria A EN61000-4-2,3,4,5,6,11, Features : P Q - 1 0 0 series ENVIRONMENT SAFETY & FUNCTION EMC (Note4) PROTECTION WITHSTANDVOLTAGE ISOLATIONRESISTANCE I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC /25 /70%RH RIPPLE&NOISE(max.) Note.2 VOLTAGETOLERANCE Note.3 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Heat Sink HS1,HS2 can not be shorted. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) Universal AC input / Full range Protections:Short circuit/Over load/Over voltage Cooling by free air convection With power good signal output(Optional) 100% full load burn-in test Fixed switching frequency at 45KHz 2 years warranty OUTPUTNUMBER CH1 CH1 CH3 CH3 CH2 CH4 CH4 100WQuadOutputSwitchingPowerSupply 12V 2A CH2 EMCIMMUNITY EMCEMISSION |
Codice articolo simile - P00 |
|
Descrizione simile - P00 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEETIT.COM |
Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |