5 / 33 page
Bolymin, Inc.
◆◆◆
4. Absolute Maximum Ratings
4.1 Electrical Absolute Maximum Ratings
(Vss=0V, Ta=25℃)
Item
Symbol
Min
Max
Unit
Supply Voltage (Logic)
Vdd-Vss
-0.3
7
V
Supply Voltage (LCD Driver)
Vdd-Vo
-0.3
13
V
Input Voltage
VI
Vss
Vdd
V
TOP
0
+50
℃
Normal Type
TSTG
-10
+60
℃
Top
-20
+70
℃
Wide Temperature Type
Tstg
-30
+80
℃
4.2 Environmental Absolute Maximum Ratings
Note (1) Ta = 0℃﹕50Hr Max.
Note (2) Ta ≦40℃:90% RH MAX
Ta > 40℃:Absolute humidity must be lower than the humidity of 90% at 40℃.
Operating
Storage
Item
(Min.)
(Max.)
(Min.)
(Max.)
Comment
Humidity
Note (2)
Note (2)
Without condensation
Vibration
--
4.9M/S
2
--
19.6M/S
2
XYZ Direction
Shock
--
29.4M/S
2
--
490M/S
2
XYZ Direction