91 / 124 page PDI Description Slave Controller – ET1100 Hardware Description III-77 6.4.6 µController access errors These reasons for µController access errors are detected by the µController interface: Read or Write access to the 16 bit interface with A[0]=1 and BHE(act. low)=1, i.e. an access to an odd address without Byte High Enable. Deassertion of WR (or deassertion of CS while WR remains asserted) while the µController interface is BUSY. Deassertion of RD (or deassertion of CS while RD remains asserted) while the µController interface is BUSY (read has not finished). A wrong µController access will have these consequences: The PDI error counter 0x030D will be incremented. For A[0]=1 and BHE(act. low)=1 accesses, no access will be performed internally. Deassertion of WR (or CS) while the µController interface is BUSY might corrupt the current and the preceding transfer (if it is not completed internally). Registers might accept write data and special functions (e.g., SyncManager buffer switching) might be performed. If RD (or CS) is de-asserted while the µController interface is BUSY (read has not finished), the access will be terminated internally. Although, internal byte transfers might be completed, so special functions (e.g., SyncManager buffer switching) might be performed. 6.4.7 EEPROM_LOADED The EEPROM_LOADED signal indicates that the µController Interface is operational. Attach a pull- down resistor for proper function, since the PDI pin will not be driven until the EEPROM is loaded. 6.4.8 Connection with 16 bit µControllers without byte addressing If the ESC is connected to 16 bit µControllers/DSPs which only support 16 bit (word) addressing, ADR[0] and BHE of the EtherCAT device have to be tied to GND, so the ESC will always perform 16 bit accesses. All other signals are connected as usual. Please note that ESC addresses have to be divided by 2 in this case. CS CS ADR[14:0] RD BUSY DATA[15:0] WR ADR[15:1] ADR[0] RD BUSY DATA[15:0] WR 16 bit µController, async, only 16 bit addressing EtherCAT device IRQ IRQ BHE General purpose input EEPROM_Loaded optional Figure 33: Connection with 16 bit µControllers without byte addressing |
Codice articolo simile - ET1100 |
|
Descrizione simile - ET1100 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEETIT.COM |
Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |