Motore di ricerca datesheet componenti elettronici |
|
K-LD2 Scheda tecnica(PDF) 16 Page - RFbeam Microwave GmbH |
|
K-LD2 Scheda tecnica(HTML) 16 Page - RFbeam Microwave GmbH |
16 / 20 page © RFbeam Microwave GmbH | Schuppisstrasse 7 | CH-9016 St. Gallen | www.rfbeam.ch | K-LD2 | data sheet 09/2018 - Revision B | Page 16/20 Param. Default Min Max Name Description D00 01 00 09 Hold time Index value to select an element of the hold time array defined with the parameters A00…A09. This value has no effect if the parameter use hold time potentiometer S0C is enabled. D01 07 00 09 Sensitivity Index value to select an element of the sensitivity array defined with the parameters A10…A19. This value has no effect if the parameter use sensitivity potentiometer S0D is enabled. D02 03 00 10 Immunity Value to change the immunity against interferences like vibrations. 00: minimum immunity 10: maximum immunity Immunity increases the reaction time of the sensor. D03 02 00 02 Direction to detect Defines which direction is detected in the detection algorithm. 00: only forward (approaching) 01: only backward (receding) 02: both directions D04 00 00 7F Low speed limit Can be used to define a low speed limit in bin for the detection algorithm to filter out slow speeds. 00: inactive 01…7F: All speeds below this bin are filtered out D05 00 00 7F High speed limit Can be used to define a high speed limit in bin for the detection algorithm to filter out fast speeds. 00: inactive 01…7F: All speeds above this bin are filtered out D06 00 00 7F Speed range threshold Function to divide the spectrum in a high and a low speed range. Triggers the range flag in the detection register R00. 00: inactive 01…7F: threshold in bin for the low and high speed range D07 06 05 09 Micro detection threshold Function to set the threshold of the micro detection feature. 05: minimum threshold 09: maximum threshold D08 02 00 0A FFT filter width Defines the ± width in bin that is filtered out around a specified filter in the FFT filter array defined with the parameters A20…A27. Param. Default Min Max Name Description A00… A09 See table below 0000 FFFF Hold time array 10 elements wide hold time array in 100 ms, addressed by parameter D00. 0000: minimum hold time 0002: 2*100 ms " 0.2 s hold time FFFF: maximum hold time A10… A19 See table below 0000 00FF Sensitivity array 10 elements wide sensitivity array in dB, addressed by parameter D01. 0000: maximum sensitivity 000A: 10 dB sensitivity 00FF: minimum sensitivity A20… A27 0 0000 007F FFT filter array FFT filter array in bin to define up to 8 different FFT filters with a ± width defined by parameter D08. 0000: FFT filter inactive 0001…007F: FFT filter position in bin Param. A00 A01 A02 A03 A04 A05 A06 A07 A08 A08 Value [Hex] 0002 0005 000A 0014 0032 0064 00C8 0190 0320 0640 Value [s] 0.2 0.5 1 2 5 10 20 40 80 160 Param. A10 A11 A12 A13 A14 A15 A16 A17 A18 A19 Value [Hex] 0022 001C 0016 0012 000E 000A 0006 0004 0002 0000 Value [dB] 34 28 22 18 14 10 6 4 2 0 Table 9: Class D 8-Bit detection parameters Table 10: Class A 16-Bit array parameters Table 11: Hold time array default values Table 12: Sensitivity array default values |
Codice articolo simile - K-LD2 |
|
Descrizione simile - K-LD2 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEETIT.COM |
Lei ha avuto il aiuto da alldatasheet? [ DONATE ] |
Di alldatasheet | Richest di pubblicita | contatti | Privacy Policy | scambio Link | Ricerca produttore All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |